0 item(s) - £0.00

Candle - Fairy Dust (8%) Safety Data Sheet

Version:            1

Section 1. Identification of the substance or the mixture and of the supplier

1.1 Product Identifier

Product identifier:          Candle - Fairydust (8%) Other identifiers:         None

1.2 Relevant identified uses of the substance of mixture and uses advised against

Product uses:                 Indoor Candle

1.3 Details of the supplier of the safety data sheet

Company name:

Bluesdesigns

Company address:

67 Hastings Avenue

Gosport

Hampshire

PO12 4BY

Contact:

Carla Montgomery

E-Mail address:

Bluesdesigns2014@gmail.com

Company phone:

02392 787684

1.4 Emergency telephone number

Emergency phone:          02392 787684

Section 2. Hazards identification

2.1 Classification of the substance or mixture

Classification under Regulation (EC) No 1272/2008

Class and category of danger:

Hazardous to the Aquatic Environment - Long-term Hazard Category 3 H412, Harmful to aquatic life with long lasting effects.

Classification under Directive 1999/45/EC

Hazard symbols:

None

Risk phrases:

2.2 Label elements

R52/53, Harmful to aquatic organisms, may cause long-term adverse effects in the aquatic environment.

Signal word:

None

Hazard statements:

H412, Harmful to aquatic life with long lasting effects.

Supplemental Information:

EUH208, Contains 1-(1,2,3,4,5,6,7,8-Octahydro-2,3,8,8-tetramethyl-2-naphthalenyl)ethanone, Geranyl acetate, alpha-iso-Methylionone, d-Limonene, dl-Citronellol, p-t-Butyl-alphamethylhydrocinnamic aldehyde. May produce an allergic reaction.

Version:            1

Precautionary statements:

P273, Avoid release to the environment.

P501, Dispose of contents/container to approved disposal site, in accordance with local regulations.

Pictograms:

None

Other hazards:

3.2 Mixtures Contains:

None

Section 3. Composition / information on ingredients

                                                                                       REACH Registration           Classification for (DSD) Classification for (CLP)

              Name                CAS           EC                                              %

                                                                                                       No.                                        67/548/EEC                    1272/2008

Linalool                            78-70-6         201-134-4                                                  2.64%            Xi ; R38                             SCI 2-EDI 2;H315-H319,-

Linalyl acetate                 115-95-7       204-116-4                                                  1.36%            Xi ; R38                             SCI 2-EDI 2;H315-H319,-

FL 3-SCI 2-SS 1B-AH 1-EH Xn-N ; R10-R38-R43-R65d-Limonene 5989-27-5               227-813-5               0.63%      A1-EH C1;H226-H304-

R50/53

H315-H317-H410,-

Hexyl acetate                   142-92-7       205-572-7                                                  0.60%            N ; R10-R51/53                       FL 3;H226,-

1-(1,2,3,4,5,6,7,8-

Octahydro-2,3,8,8-                                                                                                                                                                 SCI 2-SS 1B-EH C1;H315-

                                          54464-57-2   259-174-3                                                  0.48%           Xi-N ; R38-R43-R51/53

tetramethyl-2-       H317-H410,naphthalenyl)ethanone

p-t-Butyl-alpha-                                                                                                                                                                        ATO 4-SCI 2-SS 1B-REP

Xn-N ; R22-R38-R43-R62methylhydrocinnamic               80-54-6   201-289-8               0.24%      2-EH C2;H302-H315-H317-

R51/53 aldehyde           H361-H411,-

SCI 2-EDI 2-SS 1B;H315dl-Citronellol          106-22-9 203-375-0               0.23%      Xi-N ; R38-R43-R51/53

H317-H319,-

alpha-iso-                                                                                                                                                                               SCI 2-SS 1B-EH C2;H315-

                                          127-51-5       204-846-3                                                  0.17%           Xi-N ; R43-R36/38-R51/53

Methylionone                                                                                                                                                                                 H317-H411,-

1,3,4,6,7,8-Hexahydro-

4,6,6,7,8,8-

1222-05-5 214-946-9 0.16% N ; R50/53 EH A1-EH C1;H410,hexamethylcyclopentagamma-2-benzopyran

SCI 2-SS 1B-EH C3;H315-

Geranyl acetate               105-87-3       203-341-5                                                  0.16%           Xi-N ; R38-R43-R51/53

H317-H412,-

FL 3-SCI 2-SS 1B-AH 1; beta-Pinene 127-91-3 204-872-5               0.03%      Xn ; R10-R38-R43-R65

H226-H304-H315-H317,-

FL 3-SCI 2-EDI 2-AH 1;

Myrcene                           123-35-3       204-622-5                                                  0.01%            Xn ; R10-R38-R65

H226-H304-H315-H319,Substances with Community workplace exposure limits, not listed above:

Not Applicable

Substances that are persistent, bioaccumulative and toxic or very persistent and very bioaccumulative, greater than 0.1%: Not Applicable

Section 4. First-aid measures

4.1 Description of first aid measures

Version:            1

Inhalation:                     Remove from exposure site to fresh air, keep at rest, and obtain medical attention.

Eye exposure:               Flush immediately with water for at least 15 minutes.  Contact physician if symptoms persist.

Skin exposure:              Remove contaminated clothes.  Wash thoroughly with soap and water.  Contact physician if

irritation persists.

Ingestion:                       Rinse mouth with water and obtain medical attention.

4.2 Most important symptoms and effects, both acute and delayed None expected, see Section 4.1 for further information.

4.3 Indication of any immediate medical attention and special treatment needed None expected, see Section 4.1 for further information.

SECTION 5: Firefighting measures

5.1 Extinguishing media

Suitable media:              Carbon dioxide, Dry chemical, Foam.

5.2 Special hazards arising from the substance or mixture

In case of fire, may be liberated:     Carbon monoxide, Unidentified organic compounds.

5.3 Advice for fire fighters:

In case of insufficient ventilation, wear suitable respiratory equipment.

Section 6. Accidental release measures

6.1 Personal precautions, protective equipment and emergency procedures:

Avoid inhalation. Avoid contact with skin and eyes. See protective measures under Section 7 and 8.

6.2 Environmental precautions:

Keep away from drains, surface and ground water, and soil.

6.3 Methods and material for containment and cleaning up:

Remove ignition sources. Provide adequate ventilation. Avoid excessive inhalation of vapours. Contain spillage immediately by use of sand or inert powder. Dispose of according to local regulations.

6.4 Reference to other sections:

Also refer to sections 8 and 13.

Version:            1

Section 7. Handling and storage

7.1 Precautions for safe handling:

Keep away from heat, sparks, open flames and hot surfaces. - No smoking. Use personal protective equipment as required. Use in accordance with good manufacturing and industrial hygiene practices.  Use in areas with adequate ventilation  Do not eat, drink or smoke when using this product.

7.2 Conditions for safe storage, including any incompatibilities:

Store in a well-ventilated place. Keep container tightly closed. Keep cool. Ground/bond container and receiving equipment. Use explosion-proof electrical, ventilating and lighting equipment. Use only non-sparking tools. Take precautionary measures against static discharge.

7.3 Specific end use(s):

Indoor Candle:  Use in accordance with good manufacturing and industrial hygiene practices.

Section 8. Exposure controls/personal protection

8.1 Control parameters

 

Workplace exposure limits:

Not Applicable

8.2 Exposure Controls

Eye / Skin Protection

Wear protective gloves/eye protection/face protection

Respiratory Protection

Under normal conditions of use and where adequate ventilation is available to prevent build up of excessive vapour, this material should not require special engineering controls.  However, in conditions of high or prolonged use, or high temperature or other conditions which increase exposure, the following engineering controls can be used to minimise exposure to personnel: a) Increase ventilation of the area with local exhaust ventilation. b) Personnel can use an approved, appropriately fitted respirator with organic vapour cartridge or canisters and particulate filters. c) Use closed systems for transferring and processing this material. Also refer to Sections 2 and 7.

Section 9. Physical and chemical properties

9.1 Information on basic physical and chemical properties

Appearance:

Not determined

Odour:

Not determined

  • PayPal
  • World Pay